Are bunds compulsory at australian worksites?

A 205-litre drum of oil stored directly on a warehouse floor can turn a small leak into a costly clean-up, a slip hazard and a potential environmental incident. So, are bunds compulsory? For many Australian workplaces that store fuels, oils, chemicals or dangerous goods, some form of secondary containment is required or strongly expected. The exact obligation depends on what is stored, how much is stored, where the site operates and the applicable regulations and standards.

A bund is not simply a plastic tray under a drum. It is a containment system designed to stop a leak, spill or container failure from reaching drains, soil, waterways or other areas of the workplace. It may be a spill pallet, drum bund, IBC bund, hard-walled storage area, flexible bund or purpose-built concrete compound. The right option is determined by the risk, not by the cheapest item that fits in the available floor space.

Are Bunds Compulsory Under Australian Rules?

There is no single Australian rule that says every container of liquid must sit in a bund. However, bunding can become compulsory through several overlapping requirements: state and territory dangerous goods laws, work health and safety duties, environmental protection requirements, planning conditions, licences, site procedures, insurer expectations and Australian Standards.

In practical terms, if a release from stored liquid could harm people, contaminate land or water, enter a stormwater drain, create a fire risk, or cause a dangerous goods incident, secondary containment should be part of the control plan. A regulator may not use the same wording in every jurisdiction, but the underlying duty is clear: hazards must be identified and controlled so far as is reasonably practicable.

For workplaces storing dangerous goods, the applicable state or territory dangerous goods regulations and relevant Australian Standards are particularly important. AS 1940 is commonly referenced for the storage and handling of flammable and combustible liquids. AS/NZS 3833 is relevant to corrosive substances. Requirements can change according to the class of dangerous goods, storage quantities, package type and whether materials are stored indoors, outdoors or in a dedicated store.

Environmental obligations also matter. Oil, coolant, fuel, chemicals and contaminated wash-down water must not be allowed to enter stormwater systems. A spill that leaves the site can result in clean-up costs, reporting obligations and enforcement action. For this reason, a bund may be necessary even where the material is not classified as dangerous goods.

When Bunding Is Usually Expected

Bunding is commonly expected where a workplace stores liquids in drums, IBCs, jerry cans, tanks or bulk containers and a credible spill pathway exists. This includes workshops holding used oil and lubricants, warehouses with chemical inventory, fuel-handling areas, marine operations, manufacturing plants, farms, transport depots and maintenance facilities.

The risk increases when storage is near stormwater pits, loading docks, unsealed ground, waterways, traffic routes or ignition sources. Outdoor storage deserves particular attention. Rainwater can fill an open bund, reduce available containment capacity and become contaminated. A covered storage area, bund cover or a managed pump-out arrangement may be needed, provided contaminated water is not discharged to stormwater.

Small quantities are not automatically exempt from sensible controls. A few containers of concentrated chemical may create a greater consequence than several drums of a lower-risk product. The product safety data sheet, or SDS, should be reviewed for incompatibilities, spill response instructions and storage information before selecting containment equipment.

Bund Capacity Is More Than a Rule of Thumb

A common design benchmark is to provide enough capacity for at least 110% of the largest container stored in the bunded area, or 25% of the total stored volume, whichever is greater. This is widely used for liquid storage, but it should not be treated as a universal answer. The relevant standard, regulator guidance, site licence or customer specification may require a different capacity.

Capacity must account for what is actually inside the bund. Racking legs, pallets, drums and stored equipment displace volume. Rainwater also reduces free capacity in external bunds. A spill pallet rated for four 205-litre drums may not be suitable for four drums plus a fifth drum temporarily placed beside it during decanting.

Compatibility is equally important. A bund for oil may not be suitable for aggressive acids, solvents or oxidising agents. Polyethylene bunds are widely used because they resist many common chemicals, while steel bunds may suit particular oils, fuels and industrial applications. Always check the chemical compatibility of the bund material with the products stored.

Selecting the Right Type of Bund

The best bund is one that matches daily operations and is used properly. A fixed bunded room may be appropriate for a high-volume chemical store. A spill pallet is often more practical for a warehouse storing drums or IBCs. Drive-over flexible bunds can suit vehicle access and temporary containment, while portable bunds are useful for maintenance work, generators and field servicing.

For drum storage, ensure the spill pallet has adequate sump capacity and safe load rating for the full drum weight. For IBCs, confirm that the bund is designed for the container footprint, filled weight and required containment volume. Do not place an IBC on a pallet intended for drums simply because it appears to fit.

Consider how material is received and dispensed. If drums are decanted, pumps, funnels and hose connections should remain within the contained area. A bund that only captures a full drum failure but leaves routine dispensing outside containment does not control the most likely spill source.

Segregation is another key consideration. Incompatible chemicals must not be stored in the same bund where a combined release could react, generate heat, release vapours or worsen the hazard. Separate containment may be necessary for acids, alkalis, oxidisers, fuels and other incompatible products.

Common Bunding Failures on Worksites

Many sites have bunding in place but still fall short because it is poorly maintained or incorrectly used. The most common issue is treating a bund as general storage. Spare pallets, empty drums, tools and rubbish take up containment capacity and prevent inspections.

Blocked or unprotected drains are another frequent weakness. Drain covers, drain seals and spill response materials should be readily available where liquids are handled. Staff need to know which drains lead to stormwater and what action to take before a spill reaches them.

Routine inspections should check for cracks, chemical attack, corrosion, accumulated liquid, overloaded pallets and damaged containers. A bund with a split wall or a drain valve left open provides only the appearance of protection. Inspection records also help demonstrate that containment controls are being actively managed.

A Practical Way to Confirm Your Requirement

Start with an inventory of every liquid stored on site, including waste oil, cleaning chemicals, fuel, coolants and maintenance products. Record quantities, container sizes, storage locations and the closest spill pathways. Then review each SDS and identify the dangerous goods classification, incompatibilities and storage advice.

Next, check the regulations and environmental requirements that apply in your state or territory, along with any lease, planning, customer or insurer conditions. For larger or higher-risk stores, seek competent dangerous goods or environmental advice rather than relying on a generic capacity calculation.

Finally, make sure the equipment supports the way the team actually works. Containment, spill kits, absorbents, drain protection and staff training should operate together. Spillmaster supplies bunding options for drums, IBCs, hazardous liquids and practical workplace containment needs, allowing buyers to match equipment to the storage task.

A bund is not always compulsory for every liquid container, but preventing a spill from becoming an environmental or safety incident is always a workplace responsibility. Choose containment based on the material, volume, location and consequence of failure, then keep it clear, compatible and ready to perform when it is needed.